Performance Evaluation of Truck Equipped with the Evaporative Cooling System during Transportation of Vegetable

Authors

  • Masniza Sairi Malaysian Agricultural Research and Development Institute (MARDI)
  • Mohd Shukry Hassan Basri
  • Nur Syafini Ghazali
  • Joanna Lee Ying Cho
  • Arina Mohd Noh
  • Yahya Sahari
  • Mohd Fazly Mail
  • Mohd Shahrir Azizan
  • Sharifah Hafiza Mohd Ramli
  • Mohd Zaffrie Mat Amin
  • Azman Hamzah
  • Azhar Mat Noor
  • Mohamad Abhar Akmal Hamid
  • Nur Izzati Muhsin
  • Mohd Hafiz Mohd Amin Tawakkal
  • Amir Redzuan Shamsulkamal
  • Shafie Alwi
  • Mohd Zaimi Zainol Abidin
  • Muhammad Aliq Jamaluddin
  • Mohd Daniel Hazeq Abdul Rashid
  • Mohd Azmirredzuan Sani

DOI:

https://doi.org/10.36877/aafrj.a0000244

Abstract

The research describes the development of an evaporative cooling system in a non-refrigerated truck for the short-term storage of vegetables during transportation. The system comprises an evaporative cooler, storage unit, power supply, control panel, and real-time data monitoring for temperature  and relative humidity. Computational fluid dynamic (CFD) simulation was conducted to investigate the temperature and airflow distributions in the evaporative-cooled storage unit for five different configurations of air inlet and outlet. The configuration of one air inlet (front — lower left) and two air outlets (top — front and back centre) of the storage unit was shown to provide  optimum temperature and airflow distributions and hence, was applied in the system modification. The functionality and performance of the modified system were then evaluated in terms of the cooling profile of the storage units and leafy vegetable quality for the fresh market. Three storage treatments for the selected vegetable were investigated, i.e., evaporative-cooled truck (T1), canvas truck (T2), and cold truck (T3) during a five-hour journey from Cameron Highlands to Serdang. The average temperature inside the storage units was T3 < T1 < T2. Evaporative-cooled truck exhibited an average temperature reduction (DT) of 10°C from the ambient condition. It also demonstrated a relative humidity of >90%, which was in agreement with the recommended relative humidity for leafy vegetable storage. Post-five-hour storage treatments, vegetable stored under T1 exhibited the least weight loss as compared to T2 and T3. The results indicated that the evaporative cooling system manages to preserve vegetable quality soon after harvesting, hence the potential to reduce postharvest loss during transportation.

Downloads

Published

2021-08-30

How to Cite

Sairi, M., Hassan Basri, M. S., Ghazali, N. S., Cho, J. L. Y., Mohd Noh, A., Sahari, Y., Mail, M. F., Azizan, M. S., Mohd Ramli, S. H., Mat Amin, M. Z., Hamzah, A., Mat Noor, A., Hamid, M. A. A., Muhsin, N. I., Mohd Amin Tawakkal, M. H., Shamsulkamal, A. R., Alwi, S., Zainol Abidin, M. Z., Jamaluddin, M. A., Abdul Rashid, M. D. H., & Sani, M. A. (2021). Performance Evaluation of Truck Equipped with the Evaporative Cooling System during Transportation of Vegetable. Advances in Agricultural and Food Research Journal, 2(2). https://doi.org/10.36877/aafrj.a0000244

Issue

Section

ORIGINAL RESEARCH ARTICLE
Abstract viewed = 254 times
PDF downloaded = 257 times